Epitome® 400 Watt Inverter Desktop Specifications

a2z Mobile Office Solutions, Inc. has "Accessories for Mobile People"
Click The Electronic Catalog™ to see the rest!



400 Watt Inverter Electrical Specifications
Output: Two 3-prong AC receptacles - North American
Input Voltage Nominal Input Voltage:
Operating Input Voltage Range:
12.5 - 13.0 VDC
10.0 - 15.0 VDC
Rated Output
Power
Continuous Output Power:
5 min. Output Power:
Surge Output Power (0.1 second):
300 W
400 W
600 W
Conditions: nominal input voltage, resistive load, at normal ambient temperature.
Surge
Performance
Must be able to start and operate all loads within power rating (examples: small to medium size hand tools, 25" TV, VCR's, computers, printers, cellphones, etc.)
Output Voltage Output Voltage @ 13VDC (no load):
Output Voltage @ 13VDC (400W resistive load):
Output Voltage @ 11VDC (load equivalent to 400W @ 13 DVC)
115 - 125 VAC
105 - 125 VAC
>105 VAC
Output Frequency Output Frequency: 60 Hz ± 4 Hz
Efficiency Optimum Efficiency:
Efficiency at 400W (at nominal input voltage):
90% min
80% min
Input No Load Current No Load Current (at nominal input voltage): Input Voltage


400 Watt inverter Hardware Protection Features
Input Over Voltage Shutdown Input Over Voltage Shutdown (at no load):
Indication:
15.0 ± 0.5 VDC
Red LED On
Input Under Voltage Alarm Input Under Voltage Alarm (at no load):
Indication:
10.7 ± 0.3 VDC
Alarm Sounds
Input Under Voltage Shutdown Input Under Voltage Shutdown (at no load):
Input Under Voltage Recovery (at no load):
Indication:
10.0 ± 0.3 VDC
12.0 ± 0.5 VDC
Red LED On
Input Fuse Protection Replaceable Internal Fuse w/socket: 40A, Auto Blade
Over Temperature Shutdown Over Temperature Shutdown (measured internally):
Over Temperature Recovery:
Indication:
65 °C +5/-10 °C
60 °C ± 5 °C
Red LED On, alarm sounds
Overload Protection Input Current Overload Shutdown Level:
Conditions: Cold start at nominal input voltage w/ 30 seconds
Output Current Overload Shutdown Level:
Conditions: Measured at nominal input voltage after 5 minutes continuous run at full load
Indication:
40.0 ± 2.0 ADC


450 ± 50W


Red LED On
Output Short Circuit Protection A short circuit may be applied to the output continuously w/o damage to any components.


To Order By Phone Call:

Toll Free: (800) 347-6222 or
(304) 296-8800 (Outside the U.S.)
Fax: (304) 296-5284

Prices do not include shipping and handling or sales tax, (if applicable.)



[ Return to Epitome Index ]

[ The Electronic Catalog™ ]

[ New Products ]

[ Go to Checkout ]



Copyright © 1995-2009, a2z Mobile Office Solutions, Inc. Epitome® is a registered trademark of a2z Mobile Office Solutions, Inc. All rights reserved. All brand names and product names used on these web pages are trademarks, or trade names of their respective holders. For further information contact: B.Lee@a2zsolutions.com